Application of Synthetic Primer
It is ready for use upon delivery (after stirring) and may be applied to a clean, grit blasted steel pipes by spraying (or brushing). For normal thicknesses (dry film thickness 20-30μm, wet film thickness 100μm). The primer coverage rate is 10 m2/liter. The wet film thickness may be regulated by ±20 μm, which will result in a variation in dry film thickness of 5μm. At 25°C ambient temperatures and under normal ventilation the drying time varies from 4-12 minutes depending on pipe temperature. During application, the pipe temperature should be between 10-50°C and at least 3°C above dew point.
Application of Synthetic Primer
It is ready for use upon delivery (after stirring) and may be applied to a clean, grit blasted steel pipes by spraying (or brushing). For normal thicknesses (dry film thickness 20-30μm, wet film thickness 100μm). The primer coverage rate is 10 m2/liter. The wet film thickness may be regulated by ±20 μm, which will result in a variation in dry film thickness of 5μm. At 25°C ambient temperatures and under normal ventilation the drying time varies from 4-12 minutes depending on pipe temperature. During application, the pipe temperature should be between 10-50°C and at least 3°C above dew point.
Storage
It should be hermetically sealed and stored at temperatures between 5°C and maximum 30°C.
Standards
Synthetic meets or exceeds all the requirements of EN 10300, type 1 and AWWA C 203.
Quality Control
All raw materials for Synthetic Primer are tested and approved in the laboratories of RAHA BITUMEN Co. Each batch is tested for compliance with the product specification and a quality certificate is provided with each delivery.
Delivery
It is available in 210-liter steel drums.
Technical Data of Synthetic Primer Type 1
| Properties | Unit | Requirement | Method of test |
| Flow Time (Cup 4 mm) | Sec | 35 to 60 | EN ISO2431 |
| Flash Point (Closed Cup) | °C | 23 | ISO 13736 |
| Volatile Matter | % | 75 | 10300, Annex H |